Communication Manager
SPC3000 series communication manager is a high integrated new 32bit
embedded intelligent communication device. It is used to collect
information of whole substation automation system and centralized
send to local back-end or remote debug centre,and at the same time
transfer the orders of back-end and centers to all measure and
controll devices that realize local and remote control. SPC
directly collect all on-site device data in small sized automation
system, and transfer to background control system by user required
communication protocol( 101,104,CDT and so on)and communication
medium(ethernet,RS232/422/485 and so on) to finish all on-site
monitoring. In big systems, it can be as function substation and
bay level that make all levers relatd to realize data transferd
through different classification and directions.
Features
To adopt Motorala 32-bit high performance microcontrollers and
commercial real-time multifunction operating system that make sure
of the product stability and operration speed.
High quality industrial element, high lever electrial design and
high density integrated circuit structure enable the device have
excellent electro-magnetic shielding and electrical isolation.The
integrated machine has no regulable element that greatly enhance
the ability of anti-interference and the reliability of the device.
Adopt good performance switch power to the device,input voltage is
DC 110~340V or AC 85~264V,output voltage is 5V,wide-range voltage
output can widely be used for different power supply enviroment.
Having high speed and reliable communitation interface such as
ethernet and serial port and CAN for system extension to strengthen
the device scalability and allocation flexibility.
Flexible on-line and off-line debugging, reliable program upgrading
and parameter download and data query functions meet the need of
ever new and faster network information age.
Be provided with great ability of self Cdiagnosis and self
Chealing, the system can be self-recoverd in a short time when
causing program operation error by outside interference or other
reasons.
Provide secondary development kit,on the basis of supporting CDT,
Polling, Modbus, DNP 3.0, 1801¡¢IEC870-5-101/102/103/104 and
communication prococol of home-abroad main electrical power
producer,it can develop special protocol according to on-site
demand.
Provide many kinds of lever-related working way that makes the
system extension and compounding more convenient and flexible.
Offer active-standby redundancy and switch function to meet all
needs of safety which user concerns. Use real time operation system
Nucleus as the platform,realize multifunction, on the basis of
communication program of message queuing,face all objects:object
programmer,communication port and communication protocol
seperately. The communication function can be real time and
reliable.
Standard 19¡±1U upper-locacted,beautiful style and convenient
screen.
Predominant performance to price ratio.One device is equal to the
total of industrial computer, SCADA software, serial device server
and switch,and never be in the ¡°Dead State¡±,more convenient for
users¡¯ local application and market competetion.
Parameter
System index Work environment requirement
? System availability
System availability¡99.98%
? System capacity ? Insert device qty one time: ¡64 insert element
supports decentralized installation. ? Transmission debug qty one
time: ¡3
? Ability of inserting communication
a) Support RS-232¡¢RS-422¡¢RS-485 communication
b)Support Lan communication, conform to IEEE802.3 stipulation,use
TCP/IP as the basic net communication protocol.
? c)Support CAN bus communication
? Communication ability with debug
a) Support synchronous digital series SDH transfer, support G.703
b)Support microwave relay communication
? Information transmission time
? Action protection event¡3s
? Failure report¡10s
Query response time ¡5s
? Environment temperature: -10¡¦~+50¡¦, the average temperature can
not surpass +35¡¦ in 24 hours;
? Storing temperature: -10 ¡¦ ~+70 ¡¦, no increase to excitation
under the limit value, no irreversible conversion to the device,
after the temperature resuming, the device can work normally;
? Relative humidity: less than 85
? Air pressure: 80 kPa ~110kPa
? Working place: deviate the datum location less than 5
? There should not be explosive medium, either the gas which can
corrode the metal and destroy the insulation or conductive media;
can not fill with vapor and exist serious mold;
? The application place must have the facilities to defend rain
,snow ,wind, sand and dusty. With abundant electrical automation
on-site application experience and great communication protocol
handling ability, SPT2000 series intelligent protocol converter is
a new pro